Electrical Safety

How to test your RCD at home

By Derek Beckley ·

Your fuse box has one switch whose only job is to save your life — and it comes with its own test button. Pressing it is completely safe, takes about thirty seconds, and costs nothing. Here's how to check an RCD is working, how often to do it, and what it means if the test fails.

What an RCD actually is

An RCD (residual current device) is the switch in your fuse box — properly called a consumer unit — that cuts the power in a fraction of a second if electricity leaks to earth. "Leaks to earth" includes leaking through a person: a nicked lawnmower lead, a damaged cable, a faulty appliance. Without an RCD, that current can deliver a fatal shock. With one, the power is gone before you've registered anything happened.

Finding it in your consumer unit

Open the flap on your consumer unit and look for the wider switch with a small button marked T or Test. In many Reading homes there's a single RCD covering half the board. Newer boards use RCBOs instead — slimmer switches, one per circuit, each with its own tiny test button. The test works exactly the same way; you just have more buttons to press.

How to test an RCD, step by step

  • Pick your moment. Nothing important should be running — computer work saved, oven off, nobody mid-shower.
  • Press the T button firmly. The switch should snap off instantly and that section of the house goes dead. That bang of the switch is the pass.
  • Reset it. Push the switch fully down and then back up — some types need pushing down first to re-latch before they'll switch on again.
  • Check the power's back. That's it. Thirty seconds, done.

How often should an RCD be tested?

The notice on newer consumer units says every six months. We suggest every three months: it costs nothing, and it keeps the mechanism moving. The easiest way to remember is to tie it to something you already do quarterly — the same weekend you do a seasonal garden tidy, say. There's a practical reason for the routine: the tripping mechanism can stick if it's never exercised, and a stuck RCD is no protection at all. Keeping it moving is the whole point of the button.

If it does not trip when you press the button

Treat that section of the board as unprotected. Stop using those circuits for anything with a plug outdoors, in the bathroom or in the kitchen, and call an electrician. An RCD that won't trip on its own test button is not protecting you.

If it trips but won't reset — or keeps tripping by itself

That's almost never a worn-out RCD. It's a fault on one of the circuits it protects, and the RCD is doing its job by refusing to stay on. Don't keep forcing it back up — it needs proper fault-finding to trace which circuit, and why.

What the button can't tell you

The test button only proves the mechanism moves. It doesn't prove the RCD trips fast enough. That takes a calibrated RCD tester measuring trip times in milliseconds, which is exactly what we do during an EICR or landlord safety report.

RCD trip times: what "fast enough" means

A standard 30 mA RCD must cut the power within 300 milliseconds when 30 mA leaks to earth, and within 40 milliseconds when five times that amount leaks. An RCD tester creates those leaks on purpose and times the response. A switch that trips on its button but takes too long under the tester has failed, and it needs replacing.

Can you test an RCD with a multimeter?

No. A multimeter measures voltage, current and resistance. It can't create a controlled leak to earth, and it can't time how quickly the RCD switches off, which is the thing that matters. Some videos show a multimeter being used around an RCD, but at best that checks whether power is present. For a home check, use the test button. For a proper test, an electrician uses a dedicated RCD tester.

How to test an RCBO

An RCBO does the job of an RCD and a circuit breaker in one, for a single circuit. Test it the same way: press its own T button, check it switches off, and switch it back on. On a board full of RCBOs, work along the row one at a time. Only one circuit goes off with each press, so you can leave the fridge circuit until last.

Quick answers

How do I test my RCD?

Press the button marked T or Test on the RCD in your consumer unit. The switch should snap off straight away. Push it back on and check the power has returned.

How often should an RCD be tested?

The notice on newer consumer units says every six months. We suggest every three months, because a mechanism that is never exercised can stick.

Can I test an RCD with a multimeter?

No. A multimeter can't create a controlled leak to earth or time the trip. Use the test button at home; an electrician uses a dedicated RCD tester.

What should a 30 mA RCD trip time be?

Within 300 milliseconds at its rated 30 mA, and within 40 milliseconds at five times that current.

What if my RCD won't trip when I press the test button?

Treat the circuits it covers as unprotected and call an electrician. An RCD that ignores its own test button isn't protecting you.

What if my RCD won't reset after the test?

It's usually a fault on one of the circuits it protects, not a broken RCD. Don't keep forcing it back on; it needs fault-finding.

When to call an electrician

  • No RCD in the fuse box at all — common in older Berkshire homes with rewireable fuses or plain breakers only.
  • The test button does nothing.
  • The RCD won't reset after tripping.
  • Nuisance tripping — it keeps going off for no obvious reason.